
16" Insulation Support
USP Connectors # IS16
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. Minimize or Learn More more... |
24" Insulation Support Wire
USP Connectors # IS24-BP
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. Minimize or Learn More more... |
Insulation Support
Acorn International # IS16-BP
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. Minimize or Learn More more... |
Insulation Supports, 24" 13 Ga
Acorn International # IS24
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. Minimize or Learn More more... |
Wall Bracing, 1 1/4"
USP Connectors # RWB114
Flat bracing packaged in roll out dispenser. Pre-embossed snap-off points can be broken off by hand (gloves recommended for safety). G90 galvanizing finish. Requires (4) 8d nails for each plate and (1) 8d nail for each stud. 664 max-load. Meets SBCCI, BOCA - NER 530 and NER 505, FL 816 and 822, L.A. City RR 25337 and RR25303, and DSA PA-076 codes. Max load is the max load vector applied at top of stud wall section, not to exceed 25'L, resisted by the combination of wall brace straps installed. Load basedon lumber with a 0.50 specific gravity and 19% or less moisture content. Minimize or Learn More more... |
Wall Bracing, 11' 3"
USP Connectors # WBT12
For use on stud walls to resist racking during framing. Can be used to replace code prescribed 1 x 4 wood let-in bracing as a framing aid. Rolled edges and t-style design give strength, rigidity, and eliminate sharp, sheared edges. Framing aid only; Do Not Use as a substitute for structural shearwall components. G60 galvanizing finish. Requires four 8d nails for each plate, one 8d nail for each stud. 291-pound max load for No.WBT10, 511-pound max for No.WBT12. Meets SBCCI, BOCA - NER 530 and NER 505, ICBO 5700, ICBO 5736; L.A. City RR25337, L.A. City RR25303; and DSA PA-076 codes. Max load is the max load vector applied at top of stud wall section, not to exceed 25'L, resisted by the combination of wall brace straps installed. Load based on during framing. Can be used to replace code prescribed 1 x 4 wood let-in bracing as a framing aid. Rolled edges and t-style design give strength, rigidity, and eliminate sharp, sheared edges. Framing aid only; Do Not Use as a substitute for structural shearwall components. G60 galvanizing finish. Requires four 8d nails for each plate, one 8d nail for each stud. 291-pound max load for No.WBT10, 511-pound max for No.WBT12. Meets SBCCI, BOCA - NER 530 and NER 505, ICBO 5700, ICBO 5736; L.A. City RR25337, L.A. City RR25303; and DSA PA-076 codes. Max load is the max load vector applied at top of stud wall section, not to exceed 25'L, resisted by the combination of wall brace straps installed. Load based on Minimize or Learn More more... |