
Double Joist Hanger, 2" x 10"
Primesource Building # LUS210-2
Galvanized double joist hanger. |
Joist hanger, 2" x 10"
Primesource Building # LUS210
Galvanized steel joist hanger. |
Joist Hanger, 2" x 8"
Primesource Building # LUS28
Galvanized joist hanger. |
Slant Joist Hanger Triple Zinc, 2" x 8"
USP Connectors # JUS28-2TZ
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 2038; SBCCI 9851B, BOCA 2112, BOCA 98-15; L.A. City RR25327 & RR25361; Dade County, FL 98-0421.06 & 97-1215.07 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Double Joist Support, 2" x 10-12"
USP Connectors # JUS210-2
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 2038; SBCCI 9851B, BOCA 2112, BOCA 98-15; L.A. City RR25327 & RR25361; Dade County, FL 98-0421.06 & 97-1215.07 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Double Joist Support, 2" x 6-8"
USP Connectors # JUS26-2
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 2038; SBCCI 9851B, BOCA 2112, BOCA 98-15; L.A. City RR25327 & RR25361; Dade County, FL 98-0421.06 & 97-1215.07 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Double Stud Shoe, 16 Ga Galvanized
USP Connectors # STS2
Typically used with 2" OD pipe to reinforce joists, plates, studs, or rafters which have been drilled or notched during construction. Do Not Use as a total member replacement in structural applications. G90 galvanized finish. Single stud requires ten 10dx 1-/12 fasteners, double stud requires twelve 10d, and triple stud requires fourteen 10d for installation. 2" maximum hole size. Minimize or Learn More more... |
Face Mount Hanger, 4" x 4"
USP Connectors # SUH44
Framing connectors for floor systems, deck projects, other joist to header applications, and for light truss applications. Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. 16 gauge steel construction. G60 galvanizing finish. Meets ICBO, SBCCI, BOCA - NER 505, ICBO 2039; ICBO 2725, L.A. City RR23888, L.A. City RR25104; DSA PA076 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP LumberConnectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Grabber Joist Jaw, Steel
Grabber Construction # GJJ2
Holds up rafters and joists, eliminating the need for two people. Automatically levels the crossmember with the rimjoist or ledger giving the framer a "hands free" position while installing the joist hanger or other connectors. Clamps down on target fromthe top or the bottom and holds lumber tight. Reusable and made of zinc plated durable steel. For all 2x wood framing or less. Decking, roofing, and flooring applications. Includes 2 joist jaws per package. Minimize or Learn More more... |
Joist Angle, 1 1/2" x 1 1/2" x 1 1/4"
USP Connectors # JA1
Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. G60 galvanizing finish. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Joist Hanger 2" x 10-12-14" 20 Ga
USP Connectors # JL210
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G60 galvanizing finish. Meets ICBO, SBCCI, BOCA - NER 505; ICBO 2039, L.A. City RR23888, L.A. City RR25303; DSA PA-076; and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Joist Hanger, 2 1/2" x 14"
USP Connectors # THF25140
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets SBCCI, BOCA - NER 478, L.A. City RR 25283, FL815, & DSA PA-076. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degreeangle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Hanger, 2 1/2" x 9 1/4"
USP Connectors # THF25925
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets SBCCI, BOCA - NER 478, L.A. City RR 25283, FL815, & DSA PA-076. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degreeangle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Hanger, 2 5/16" x 11 1/4"
USP Connectors # THF23118
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets SBCCI, BOCA - NER 478, L.A. City RR 25283, FL815, & DSA PA-076. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degreeangle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Hanger, 2 5/16" x 14"
USP Connectors # THF23140
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets SBCCI, BOCA - NER 478, L.A. City RR 25283, FL815, & DSA PA-076. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degreeangle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Hanger, 2 5/16" x 9 1/4"
USP Connectors # THF23925
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets SBCCI, BOCA - NER 478, L.A. City RR 25283, FL815, & DSA PA-076. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degreeangle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Hanger, 2 x 8-10
USP Connectors # JL28
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G60 galvanizing finish. Meets ICBO, SBCCI, BOCA - NER 505; ICBO 2039, L.A. City RR23888, L.A. City RR25303; DSA PA-076; and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Minimize or Learn More more... |
Joist Hanger, 2" x 10-12"
USP Connectors # JUS210
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets SBCCI, BOCA - NER 608, ICBO 5356, ICBO 2039, L.A. City RR 25327 & RR 25361, FL571, FL821, Dade County, FL 01-0417.11 - JUS (2) 2x, 3x, & 4x models except JUS214-2, JUS414, & JUS214-3 Dade County, FL 01-0327.04 - JUS 2x model codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Minimize or Learn More more... |
Joist Hanger, 2" x 11 1/4"
USP Connectors # THF20112
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets SBCCI, BOCA - NER 478, L.A. City RR 25283, FL815, & DSA PA-076. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degreeangle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Hanger, 2" x 11 7/8"
USP Connectors # THO20118
Engineered for I-Joist to header applications. Offers full lateral support of the I-Joist top chord. Raised dimple nailing guides help assure correct 45 degree nailing into the I-Joist bottom flange. Features the "Seat Cleat" that allows for quick, positive seating. "Seat Cleat" holds I-Joist in place, eliminating spring-back during nailing in the bottom flange. G90 galvanizing finish. Meets ICC-ES ESR-1178, SBCCI, BOCA - NER 478 & NER 530, ICBO 2039, ICBO 3613, FL815, FL822, L.A. City RR 23888, RR 25283, & RR25337, DSA PA-076. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Hanger, 2" x 14"
USP Connectors # THF20140
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets SBCCI, BOCA - NER 478, L.A. City RR 25283, FL815, & DSA PA-076. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degreeangle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |