Joist Hanger, 2" x 11 7/8"
USP Connectors # THO20118
Engineered for I-Joist to header applications. Offers full lateral support of the I-Joist top chord. Raised dimple nailing guides help assure correct 45 degree nailing into the I-Joist bottom flange. Features the "Seat Cleat" that allows for quick, positive seating. "Seat Cleat" holds I-Joist in place, eliminating spring-back during nailing in the bottom flange. G90 galvanizing finish. Meets ICC-ES ESR-1178, SBCCI, BOCA - NER 478 & NER 530, ICBO 2039, ICBO 3613, FL815, FL822, L.A. City RR 23888, RR 25283, & RR25337, DSA PA-076. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Hanger, 2" x 14"
USP Connectors # THO20140
Engineered for I-Joist to header applications. Offers full lateral support of the I-Joist top chord. Raised dimple nailing guides help assure correct 45 degree nailing into the I-Joist bottom flange. Features the "Seat Cleat" that allows for quick, positive seating. "Seat Cleat" holds I-Joist in place, eliminating spring-back during nailing in the bottom flange. G90 galvanizing finish. Meets ICC-ES ESR-1178, SBCCI, BOCA - NER 478 & NER 530, ICBO 2039, ICBO 3613, FL815, FL822, L.A. City RR 23888, RR 25283, & RR25337, DSA PA-076. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Hanger, 2" x 14"
USP Connectors # THF20140
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets SBCCI, BOCA - NER 478, L.A. City RR 25283, FL815, & DSA PA-076. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degreeangle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Hanger, 2" x 4-6" 20 Ga
USP Connectors # JL24
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G60 galvanizing finish. Meets ICBO, SBCCI, BOCA - NER 505; ICBO 2039, L.A. City RR23888, L.A. City RR25303; DSA PA-076; and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Minimize or Learn More more... |
Joist Hanger, 2" x 6"-8"
USP Connectors # JL26
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G90 galvanizing finish. Meets ICBO, SBCCI, BOCA - NER 505; ICBO 2039, L.A. City RR23888, L.A. City RR25303; DSA PA-076; and Dade County, FL 97-1215.07 cod Minimize or Learn More more... |
Joist Hanger, 2" x 9 1/4"
USP Connectors # THF20925
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets SBCCI, BOCA - NER 478, L.A. City RR 25283, FL815, & DSA PA-076. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degreeangle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Joist Support, 2" x 4"
USP Connectors # JUS24
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 9747, SBCCI 9851A; BOCA 97-39, BOCA 98-15, L.A. City RR25327, L.A. City RR25361; Dade County, FL 98-0421.06 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Joist Support, 2" x 6"
USP Connectors # JUS26
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 9747, SBCCI 9851A; BOCA 97-39, BOCA 98-15, L.A. City RR25327, L.A. City RR25361; Dade County, FL 98-0421.06 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Joist Support, 2" x 8"
USP Connectors # JUS28
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 9747, SBCCI 9851A; BOCA 97-39, BOCA 98-15, L.A. City RR25327, L.A. City RR25361; Dade County, FL 98-0421.06 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Ring Barb Joist Hanger Nails, 1 1/2"
USP Connectors # NA11-1MC
Structurally rated. For use with USP Lumber Connectors' products. Hot dipped galvanized finish for corrosion resistance. For additional information including withdrawal load and allowable shear per nail, Please See USP Lumber Connectors charts in the Orgi Minimize or Learn More more... |
Skewed 45 Degree Hanger 2" x 8-10-12"
USP Connectors # SKH28L
Standard stock 45 degree skew for the most common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. G60 galvanizing finish. Meets ICBO, SBCCI, BOCA - NER 478; L.A. City RR25283; DSA PA-076 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Skewed 45 Degree Hanger 2" x 8-10-12"
USP Connectors # SKH28R
Standard stock 45 degree skew for the most common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. G60 galvanizing finish. Meets ICBO, SBCCI, BOCA - NER 478; L.A. City RR25283; DSA PA-076 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Skewed Hanger, 2 x 6-8"
USP Connectors # SKH26L-TZ
Standard stock 45 degree skew for the most common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICBO, SBCCI, BOCA - NER 478; L.A. City RR25283; DSA PA-076 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Minimize or Learn More more... |
Skewed Hanger, 2" x 10-14
USP Connectors # SKH210L-TZ
Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICBO, SBCCI, BOCA - NER 478; L.A. City RR25283; DSA PA-076 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Minimize or Learn More more... |
Skewed Triple Zinc Hanger, 7 1/4"
USP Connectors # SKH28R-TZ
Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICBO, SBCCI, BOCA - NER 478; L.A. City RR25283; DSA PA-076 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Minimize or Learn More more... |
Skewed Triple Zinc Hanger, 7 1/4"
USP Connectors # SKH28L-TZ
Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICBO, SBCCI, BOCA - NER 478; L.A. City RR25283; DSA PA-076 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Minimize or Learn More more... |
Slant Joist Hanger Triple Zinc, (2)2" x 6"
USP Connectors # JUS26-2TZ
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 2038; SBCCI 9851B, BOCA 2112, BOCA 98-15; L.A. City RR25327 & RR25361; Dade County, FL 98-0421.06 & 97-1215.07 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Slant Joist Hanger Triple Zinc, 2" x 10"
USP Connectors # JUS210-2TZ
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 2038; SBCCI 9851B, BOCA 2112, BOCA 98-15; L.A. City RR25327 & RR25361; Dade County, FL 98-0421.06 & 97-1215.07 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Slant Joist Hanger Triple Zinc, 2" x 10"
USP Connectors # JUS210-TZ
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 9747, SBCCI 9851A; BOCA 97-39, BOCA 98-15, L.A. City RR25327, L.A. City RR25361; Dade County, FL 98-0421.06 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Slant Joist Hanger Triple Zinc, 2" x 4"
USP Connectors # JUS24-TZ
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 9747, SBCCI 9851A; BOCA 97-39, BOCA 98-15, L.A. City RR25327, L.A. City RR25361; Dade County, FL 98-0421.06 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Slant Joist Hanger Triple Zinc, 2" x 6"
USP Connectors # JUS26-TZ
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 9747, SBCCI 9851A; BOCA 97-39, BOCA 98-15, L.A. City RR25327, L.A. City RR25361; Dade County, FL 98-0421.06 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |