
Slant Joist Hanger Triple Zinc, 2" x 8"
USP Connectors # JUS28-TZ
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 9747, SBCCI 9851A; BOCA 97-39, BOCA 98-15, L.A. City RR25327, L.A. City RR25361; Dade County, FL 98-0421.06 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Slant Nail Double Joist Hanger, 2" Gold Coated
USP Connectors # JUS26-2GC
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO 5441, SBCCI 2038; SBCCI 9851B, BOCA 2112, BOCA 98-15; L.A. City RR25327 & RR25361; Dade County, FL 98-0421.06 & 97-1215.07 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Minimize or Learn More more... |
Slant Nail Gold Coated Double Joist Hanger, 2"
USP Connectors # JUS210-2GC
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO 5441, SBCCI 2038; SBCCI 9851B, BOCA 2112, BOCA 98-15; L.A. City RR25327 & RR25361; Dade County, FL 98-0421.06 & 97-1215.07 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Minimize or Learn More more... |
Slant Nail Hanger 2 2" x 8-10" 18 Ga
USP Connectors # JUS28-2
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICBO 5356, ICBO5441, SBCCI 2038; SBCCI 9851B, BOCA 2112, BOCA 98-15; L.A. City RR25327 & RR25361; Dade County, FL 98-0421.06 & 97-1215.07 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. Minimize or Learn More more... |
Slant Nail Joist Hanger, 2" x 10"-12" Gold Coated
USP Connectors # JUS210-GC
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets SBCCI, BOCA - NER 608, ICBO 5356, ICBO 2039, L.A. City RR 25327 & RR 25361, FL571, FL821, Dade County, FL 01-0417.11 - JUS (2) 2x, 3x, & 4x models except JUS214-2, JUS414, & JUS214-3 Dade County, FL 01-0327.04 - JUS 2x model codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Minimize or Learn More more... |
Slant Nail Joist Hanger, 2" x 6"-8" Gold Coated
USP Connectors # JUS26-GC
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets SBCCI, BOCA - NER 608, ICBO 5356, ICBO 2039, L.A. City RR 25327 & RR 25361, FL571, FL821, Dade County, FL 01-0417.11 - JUS (2) 2x, 3x, & 4x models except JUS214-2, JUS414, & JUS214-3 Dade County, FL 01-0327.04 - JUS 2x model codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Minimize or Learn More more... |
Stud Shoe Single Stud
USP Connectors # STS1
|
Top Mount Joist Hanger, 11 7/8" x 2 1/2"
USP Connectors # TFL25118
Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1178, SBCCI, BOCA - NER 478 & NER 530, ICBO 2039, ICBO 3613, FL815, FL822, L.A. City RR 23888, RR 25283, & RR25337, DSA PA-076. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Top Mount Joist Hanger, 11 7/8" x 2 5/16"
USP Connectors # TFL23118
Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1178, SBCCI, BOCA - NER 478 & NER 530, ICBO 2039, ICBO 3613, FL815, FL822, L.A. City RR 23888, RR 25283, & RR25337, DSA PA-076. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Top Mount Joist Hanger, 14" x 2 1/2"
USP Connectors # TFL2514
Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1178, SBCCI, BOCA - NER 478 & NER 530, ICBO 2039, ICBO 3613, FL815, FL822, L.A. City RR 23888, RR 25283, & RR25337, DSA PA-076. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Top Mount Joist Hanger, 14" x 2 5/16"
USP Connectors # TFL2314
Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1178, SBCCI, BOCA - NER 478 & NER 530, ICBO 2039, ICBO 3613, FL815, FL822, L.A. City RR 23888, RR 25283, & RR25337, DSA PA-076. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Top Mount Joist Hanger, 2" x 9 1/2"
USP Connectors # THO20950
Engineered for I-Joist to header applications. Offers full lateral support of the I-Joist top chord. Raised dimple nailing guides help assure correct 45 degree nailing into the I-Joist bottom flange. Features the "Seat Cleat" that allows for quick, positive seating. "Seat Cleat" holds I-Joist in place, eliminating spring-back during nailing in the bottom flange. G90 galvanizing finish. Meets ICC-ES ESR-1178, SBCCI, BOCA - NER 478 & NER 530, ICBO 2039, ICBO 3613, FL815, FL822, L.A. City RR 23888, RR 25283, & RR25337, DSA PA-076. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Top Mount Joist Hanger, 9 1/2" x 2 1/2"
USP Connectors # TFL2595
Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1178, SBCCI, BOCA - NER 478 & NER 530, ICBO 2039, ICBO 3613, FL815, FL822, L.A. City RR 23888, RR 25283, & RR25337, DSA PA-076. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Top Mount Joist Hanger, 9 1/2" x 2 5/16"
USP Connectors # TFL2395
Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1178, SBCCI, BOCA - NER 478 & NER 530, ICBO 2039, ICBO 3613, FL815, FL822, L.A. City RR 23888, RR 25283, & RR25337, DSA PA-076. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Minimize or Learn More more... |
Tripe Zinc Skew Hanger, 2" x 6"- 8"
USP Connectors # SKH26R-TZ
Standard stock 45 degree skew for the most common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICBO, SBCCI, BOCA - NER 478; L.A. City RR25283; DSA PA-076 and Dade County, FL 97-1215.07 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Minimize or Learn More more... |
Triple Stud Shoe
USP Connectors # STS3
Typically used with 2" OD pipe to reinforce joists, plates, studs, or rafters which have been drilled or notched during construction. Do Not Use as a total member replacement in structural applications. G90 galvanized finish. Single stud requires ten 10dx 1-/12 fasteners, double stud requires twelve 10d, and triple stud requires fourteen 10d for installation. 2" maximum hole size. Minimize or Learn More more... |